American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.202 Panduan Petunjuk Instalasi - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Perabotan Dalam Ruangan American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.202. American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.202 12 halaman. American standard selectronic innsbrook electronic lavatory faucet speciifcation sheet
Juga untuk American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.202: Daftar Bagian (1 halaman), Lembar Spesifikasi (1 halaman)

American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.202 Panduan Petunjuk Instalasi
FAQ'S
Q: How will I know if battery needs to be replaced?
A: Valve does not open and sensor blinks 2 times
interrupted by pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced
significantly?
A: Check and clean aerator and strainer.
Q: There is no flow out of faucet when I'm in the
sensor range?
A: Check sensor. If sensor blinks 2 times interrupted
by pause, replace battery, or call 1800-442-1902.
Q: Why does the faucet operate the opposite of
expected-Turns On when not in sensor range, but
turns off when in sensor range?
A: Sensor wires to solenoid are reversed. Black to -
& Red to + is correct.
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging
from 20-80 psi.