Da-Lite TENSIONED CONTOUR ELECTROL Buku Petunjuk - Halaman 5

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Aksesori Proyektor Da-Lite TENSIONED CONTOUR ELECTROL. Da-Lite TENSIONED CONTOUR ELECTROL 9 halaman. Installer friendly features
Juga untuk Da-Lite TENSIONED CONTOUR ELECTROL: Buku Instruksi (13 halaman), Buku Instruksi (9 halaman), Panduan Pemasang (2 halaman), Buku Instruksi (13 halaman)

Da-Lite TENSIONED CONTOUR ELECTROL Buku Petunjuk
TENSIONEd CONTOUR
120V WIRING DIAGRAM
FOR STANDARD

WALL SWITCH

JunCTIon boX
loCaTed In lefT endCaP
gRound–musT be ConneCTed
To buIldIng gRound
aC (Common)
sPdT sWITCh WITh
CenTeR off
blaCk
uP
aC hoT 120VaC 60hZ 1 amP
off
blaCk/YelloW
doWn
Red
noTe: a sIngle sWITCh CannoT be used To oPeRaTe moRe Than
one sCReen. ConTaCT The faCToRY foR fuRTheR
ThIs sWITCh Can noT
InfoRmaTIon.
be used WITh lVC.
120V WIRING DIAGRAM WITH
OPTIONAL BUILT-IN VIDEO
PROjECTOR INTERFACE
CAUTION: THE PROjECTOR MUST BE TURNED OFF BEFORE CONNECTING THE
TRIGGER WIRES TO THE PROjECTOR. FAILURE TO DO SO MAY DAMAGE THE
CONTROLLER.
use 2-conductor 20-24 gauge wire to extend the low voltage connection
from the projector's 5 or 12-volt screen trigger output to the length
required to reach the VPI. When extending the low voltage connection
from the projector's screen trigger output polarity does not matter. The
red and black wires from the VPI are interchangeable.
IMPORTANT NOTE:
The wall switch is ReQuIRed to make any limit switch adjustments,
eVen if a third party control system is used. Therefore, it is advised to
wire the switch or provide a 3-conductor connection that is accessible.
3-conductor 20-24 gauge wire can be used in place of the supplied RJ-14
cable to connect the wall switch. Connect the bus terminals on the wall
switch to the corresponding bus terminals on the splitter board.
240V WIRING DIAGRAM WITH
OPTIONAL BUILT-IN VIDEO
PROjECTOR INTERFACE
CAUTION: THE PROjECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO
THE PROjECTOR. FAILURE TO DO SO MAY DAMAGE THE CONTROLLER.
1.
use 2-conductor 20-24 gauge wire to extend the low voltage connection from the
projector's 5 or 12-volt screen trigger output to the length required to reach the VPI.
When extending the low voltage connection from the projector's screen trigger output,
be sure to maintain the proper polarity. The red wire from the VPI is the "signal" and the
black wire from the VPI is the "ground".
2.
Connect the wires from the VPI that are labeled "low Voltage Connection" to the end
of the extended screen trigger wires above.
ELECTROL
INSTALLATION
®
®
WhITe
blaCk
moToR
Red
gReen
gRound To Case
240 VOLT WIRING DIAGRAM FOR STANDARD
WALL SWITCH:
da-lite offers two styles of 240 volt wall
switches for standard operation. Please see
wiring diagram included in wall switch box
included with screen.
led
uP lImIT
TaCTIle
buTTon
U P
RJ-22
JaCk
S T O
P
D O W
N
doWn
bus
lImIT
TaCTIle
buTTon
fRonT of
baCk of
Wall sWITCh
Wall sWITCh
blaCk
Red
5/12 VolT sCReen
TRIggeR on PRoJeCToR
bRoWn
blue
240VaC/50hZ
PoWeR souRCe
gReen/YelloW
(gRound)
Red
blaCk
WhITe
fRonT of
baCk of Wall
Wall sWITCh
sWITCh
uP
sToP
doWn
4
RJ-22 JaCk
RJ-22 ouTPuT
RJ-22
uP
dRY ConTaCTs
InPuTs
doWn
Common
bus
bus
5V
RJ-45
ReCePTaCle
RJ-45
JaCk
PoWeR
WIRe
VPI TRIggeR
gReen (gRound)
module
blaCk (hoT)
gRound–musT be ConneCTed
WhITe (Common)
To buIldIng gRound
POWER INPUT 120VAC / 60HZ
gReen/YelloW
bRoWn
blue
blaCk (uP)
(hoT)
(Common)
Red
blaCk
5/12 VolT sCReen TRIggeR on PRoJeCToR
daTa
Cable
(gRound)
(doWn)
(Common)