Ekinex EK-HE1-TP Manual - Halaman 4

Jelajahi secara online atau unduh pdf Manual untuk Pengontrol Ekinex EK-HE1-TP. Ekinex EK-HE1-TP 5 halaman. Actuator / controller for electrothermal actuators

Ekinex EK-HE1-TP Manual
i
Note. When using in installations with 4-pipe
hydraulic distribution, the outputs have to be used
respecting the coupling between the channel pairs
1A-1B, 2A-2B, 3A-3B, 4A-4B.
Connection in 2-pipe systems
230 Vac or
24 Vac
3A
9
1A
1
1 2
Valve actuator

Configuration and commissioning

Configuration and commissioning of the device require
the use of the ETS
(Engineering Tool Software) program
®
V4 or later releases. These activities must be carried out
according to the design of the building automation system
done by a qualified planner.
i
Note. The configuration and commissioning of KNX
devices require specialized skills. To acquire these
skills, you should attend the workshops at KNX cer-
tified training centers.
Configuration
For the configuration of the device parameters the corre-
sponding application program or the whole ekinex
duct database must be loaded in the ETS program. For
detailed information on configuration options, refer to the
application manual of the device available on the website
www.ekinex.com.
Product
Application program
code
(## = release)
EK-HE1-TP
APEKHE1TP##.knxprod
Commissioning
For commissioning the device the following activities are
required:
• make the electrical connections as described above;
• turn on the bus power supply;
• switch the device operation to the programming mode
by pressing the programming pushbutton located on
the front side of the housing. In this mode of operation,
the programming LED is turned on;
• download into the device the physical address and the
configuration with the ETS
L
N
3B
4A
4B
L
N
N
10
11
12
13
14
15
16
1B
2A
2B
L
N
N
2
3
4
5
6
7
8
Area
Line
Dev.
bus KNX
®
Communica-
Group
tion objects
adresses
(nr. max)
(nr. max)
244
244
program.
®
At the end of the download the operation of the device
automatically returns to normal mode; in this mode the
programming LED is turned off. Now the bus device is
programmed and ready for use.
Reset of the device
To reset the device remove the bus connection by ex-
tracting the bus terminal from its seat. Keeping pressed
the programming pushbutton, reinsert the bus terminal in
his seat; the programming LED blinks fast. Release the
programming button and remove the bus terminal again;
the reset was carried out. Now you need to address and
configure again the device via ETS.
Warning! The reset restores the device back to the
!
state of delivery from the factory. The address and
the value of the parameters set during configuration
will be lost.
Dimensions [mm]
3A
3B
4A
9
10
11
1A
1B
2A
1
2
3
bus KNX
Marks
• KNX
• CE: the device complies with the Low Voltage Directi-
ve (2014/35/EC) and the Electromagnetic Compatibili-
ty Directive (2014/30/EC). Tests carried out according
to EN 50491-2:2010, EN 50491-3:2009, EN 50491-
4-1:2012, EN 50491-5-1:2010, EN 50491-5-2:2010,
EN 50428:2005 +A1:2007 + A2:2009
pro-

Maintenance

The device is maintenance-free. To clean use a dry cloth.
It must be avoided the use of solvents or other aggressive
substances.
Disposal
Warning! Incorrect disposal of this product may
!
cause serious damage to the environment and hu-
man health. Please be informed about the correct
disposal procedures for waste collecting and pro-
cessing provided by local authorities.
4
72
5
25
4B
L
N
N
12
13
14
15
16
2B
L
N
N
4
5
6
7
8
Area
Line
Dev.
At the end of its useful life the product
described in this datasheet is classified
as waste from electronic equipment
and cannot be disposed together with
the municipal undifferentiated solid
waste.
70
20
20