Ekinex EK-BR1-TP Petunjuk Instalasi
Jelajahi secara online atau unduh pdf Petunjuk Instalasi untuk Peralatan Perekaman Ekinex EK-BR1-TP. Ekinex EK-BR1-TP 4 halaman.
KONNECT4, advanced IP-KNX interface for
KNX and/or Control4 installations
Codes: EK-BR1-TP
Konnect4 is a web-server designed to offer a suite
of connectivity and functional services to a Control4
supervision system, when used in combination with
ekinex KNX devices.
Description
Konnect4 server is designed for installation on DIN profile
rail and occupies 2 modules. The 12-24 Vdc power supply
is external (power supply not included). The product with
hardware based on embedded operating system, has a
KNX TP node (twisted pair) and can therefore be con-
nected directly to the bus network of KNX devices. Con-
nectivity as an IP gateway for Control4 is via the Ethernet
port. The integrated web server built with HTML5 techno-
logy allows access to the configuration environment.
With KONNECT4 it is possible to:
• Send commands and receive information from KNX de-
vices in the CONTROL4 system
• Monitor the building energy consumption and control
loads accordingly with the overall absorption with a de-
dicated graphic driver for Composer
• Make a continuous diagnostic check on the KNX de-
vices and receive notifications in case of malfunctions
• Define command sequences (scenes) and execute
them with simple connections in Composer with 3rd
party drivers
• Perform logics configurable with a graphic editor and
executed in background
• Send notifications to CONTROL4 in case of malfun-
ctions or configurable events on the bus
Main features
• 12-24 Vdc power supply (absorption 240 mA at 12 Vdc)
by means of a special plug-in terminal supplied. Power
supply not included
• KNX TP bus (twisted pair) via red-black terminal pro-
vided
• 1 Ethernet port via cat. 5 or higher cable and standard
RJ45 connector
• 1 RS485 port for future integrations
• 1 USB 2.0 port: for future integrations
• 2 frontal LEDs: POWER LED for signalling the pre-
sence of power supply; SERVICE LED for signalling
Technical Sheet STEKBR1TP_EN
particular operations in progress
• 1 RESET button housed under the front cover on the
back of the vertical card
Other features:
• Plastic housing
• Design for mounting on 35 mm profile rail (according
to EN 60715)
• Degree of protection IP20 with product installed (accor-
ding to EN 60529)
• Insulation class II (according to EN 60335-1
• Climatic classification 3K5 (indoor, dry) and mechanical
3M2 (according to EN50491-2)
• Device weight: 120 g
• 2 UM modular device (1 UM = 18 mm)
• Dimensions 36 x 90.5 x 62 mm (W x H x D)
Environmental conditions:
• Operating temperature: 0°C ... + 40°C
• Storage temperature: - 10 ... + 70°C
• Transport temperature: - 10 ... + 70°C
• Relative humidity: 95% non-condensing
Operating, signaling and connection elements
Konnect4 server is equipped with status LEDs, a RESET
button located under the front panel of the device, ter-
minals for power supply connection, KNX bus line and
Ethernet network. The server offers also an USB and
RS485 port, prepared for future use (not available at the
present moment in the configuration process).
6
8
7
4
1. LED SERVICE
2. LED POWER
3. RESET push-button
4. Clamp for power-supply 12-24 Vdc
5. Clamp for KNX bus
6. RJ45 Ethernet plug
7. Clamp for RS485 network
8. 2.0 USB port
Signaling elements
• POWER LED: indicates the presence of 12-24 Vdc po-
wer supply at terminals
• SERVICE LED: Normally off, steady mode or flashing
during IP address recovery sequences or factory re-
configurations
Control elements
• RESET button: must be pressed to activate IP address
reset sequences or factory settings.
1
1
2
5
3