American Standard SELECTRONIC 2506.1X3 Panduan Petunjuk Instalasi - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Perlengkapan Dapur & Kamar Mandi American Standard SELECTRONIC 2506.1X3. American Standard SELECTRONIC 2506.1X3 10 halaman. Moments proximity faucets
MOUNT ENCLOSURE; Fig. 2
2
etermine location of ENCLOSURE (1). It must be
1. D
located with-in the 14" (356mm) by 21" (533mm)
shaded area shown in Figure 2 in order for electrical
connections from the spout assembly to be made.
NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance
between wall supply and ENCLOSURE (1) must be
taken into consideration.
2. Remove 4 screws from ENCLOSURE COVER (2)
and pull off COVER (2). Hold the ENCLOSURE (1)
in desired location and mark the four mounting hole
locations as shown.
NOTE: For AC installation, make power supply
connection before mounting ENCLOSURE (1) to wall.
3. It is recommended that the ENCLOSURE (1) be secured
to a wall stud or cross brace within the wall using the
SCREWS (3) supplied. If the ENCLOSURE (1) is to be
installed on tile or plaster walls, the ANCHORS (4) and
SCREWS (3) should be used.
CONNECT SPOUT HOSE TO
3
ENCLOSURE; Fig. 3
1. Connect SUPPLY NUT (1) from spout hose to nipple on
top of ENCLOSURE (2). Tighten with adjustable wrench
to make a water tight connection. Fig. 3.
CONNECT WATER SUPPLY TO
4
ENCLOSURE AND WALL SUPPLY;
Fig. 4, 4a
NOTE; If using the optional Mixing Valve See Sheet
#M968808 for installation instructions.
1. Insert FIBER WASHER (4) into SUPPLY NUT (1) on
ENCLOSURE (2).
2. Connect FLEXIBLE SUPPLY HOSE (3) to SUPPLY
NUT (1) on ENCLOSURE (2). Tighten to make a
water tight connection. Use two wrenches to tighten
if necessary. Fig. 4.
3. Connect FLEXIBLE SUPPLY HOSE (3) directly to wall
supply. Connection on FLEXIBLE SUPPLY HOSE (3)
is 3/8" compression. Use adjustable wrench to
tighten connection. Do not over tighten. Fig. 4a.
Note: FLEXIBLE SUPPLY HOSE (3) measures 20" from the
bottom of the ENCLOSURE (2) base. If additional supply
length is required, installer must purchase parts separately.
Important: If FLEXIBLE SUPPLY HOSE (3) is too long,
loop to avoid kinking.
Fig. 2
1
SUPPLIES
WASTE
20"
(500mm)
21"
(mm)
MOUNTING HOLES
4
1
NOTE: If using Mixing Valve (optional) See Sheet
#M968808 for installation instructions.
Fig. 3
1
2
Fig. 4
2
Fig. 4a
COLD WATER OR
TEMPERED
WALL SUPPLY
3
LAVATORY RIM OR
MOUNTING SURFACE
14"
(356mm)
ENCLOSURE
MOUNTING
HOLES
2-3/4"
(71mm)
3"
3-3/4"
(76mm)
(96mm)
3
1
2
1
3
3
M965653 (11/14)