HOW TO CLEAN FILTER; Fig. 4
4
Before opening ENCLOSURE
CAUTION
disconnect AC power supply.
1. Remove ENCLOSURE COVER.
2. Close SUPPLY STOP (1) with 4mm Hex wrench.
Note: Keep water flowing out of faucet while shutting off.
3. Unthread STRAINER (2) using a 7/16" socket.
4. Pull out the STRAINER (2) and clean with an old
toothbrush. Rinse thoroughly with water.
5. Install the STRAINER (2) back in its place and
tighten with a 7/16" socket.
Caution: do not over tighten strainer.
Note: It is recommended to clean strainer every 6
months.
6. Open SUPPLY STOP (1) with 4mm Hex wrench.
7. Replace ENCLOSURE COVER. Tighten cover
screws firmly.
HOW TO CLEAN AND REMOVE
5
THE FLOW RESTRICTOR; Fig. 5
1. Remove SET SCREW (1) with FLAT BLADE
SCREWDRIVER (2). Pull off SPOUT (3) from faucet
base. Fig. 5 & 5a.
2. Remove HOUSING (4) and remove FLOW
RESTRICTOR (5). Fig. 5b.
3. Rinse clean FLOW RESTRICTOR (5). Reassemble
and install into SPOUT BASE (6). Reassemble SPOUT
(3) onto SPOUT BASE (6) and tighten SET SCREW (1).
Fig. 5.