Acer X193 Panduan Servis - Halaman 29

Jelajahi secara online atau unduh pdf Panduan Servis untuk Monitor Acer X193. Acer X193 36 halaman. Acer lcd monitor user's guide
Juga untuk Acer X193: Panduan Pengguna (23 halaman)

Acer X193 Panduan Servis
ACER X193HQ
28
Go to cover page
5.9 Checking the interface circuit of sync signal
5.9.1 Checking the control circuit of horizontal sync pluse
5.9.2 Checking the control circuit of vertical sync pluse
5. Troubleshooting (continued)
Check the horizontal sync signal on P302 pin13 TTL
level.
OK
Check the horizontal sync signal on I308 pin9 TTL
level.
OK
Failure Point
Process "Checking the resolution change IC movement"
section.
Check the vertical sync signal on P302 pin14 TTL level.
OK
Check the horizontal sync signal on I308 pin8 TTL
level.
OK
Failure Point
Process "Checking the resolution change IC movement"
section.
NG
Failure Point
Video cable is failure.
Failure Point
NG
1) Printed wire broke between P302 pin13 and
I308 pin9.
2) FB304 , R309 is open.
3) D307 ,R319 or C322 is short.
NG
Failure Point
Video cable is failure.
Failure Point
NG
1) Printed wire broke between P302 pin14 and
I308 pin8.
2) FB305 or R308 is open.
3) D310,R318 or C313 is short.