Aston Global EMERALD EM1500 Panduan Pengguna - Halaman 2

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk UPS Aston Global EMERALD EM1500. Aston Global EMERALD EM1500 4 halaman.

SAVE THESE INSTRUCTIONS

This manual contains important safety instructions. Please follow all instructions carefully during
installation. Read this manual thoroughly before attempting to unpack, install or operate.
CAUTION-
To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area, free of conductive contaminants.
CAUTION-
Risk of electric shock, do not remove the cover. No user serviceable parts. Refer
servicing to qualified service personnel.
CAUTION-
Risk of electric shock, hazardous live parts inside this UPS can be energized from the
battery supply even when the input AC power is disconnected.
CAUTION-
Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage
may exist between battery terminals and ground. Test before touching.
NOTICE-
The UPS is designed to be for use with computer loads only.
1
Inspection
Inspect the UPS upon
receipt. Notify the carrier
and dealer if there is
damage. The package is
recyclable; save it for reuse
or dispose of it properly.
Inspect accessories:
Power cable 1PCS
USER MANUAL
1PCS
4
Connect Modem/ Phone / Network for Surge Protection(only for
the mode with RJ-45)
Connect a single modem/phone line
into surge-protected "IN" outlet on the
back
panel of the UPS unit. Connect from
"OUT" outlet to the computer with another phone
line cable.
7
Cold Start Function
When the UPS is off and there is no
power utility, it's still possible to cold
start the UPS unit to power the loads.
GRs - 1000 / 1500 / 2000 - LED
FRONT PANEL(STANDARD)
1. AC input outlet
2. Fuse
3. Output receptacles
USER'S MANUAL
1000VA/1500VA/2000VA
IMPORTANT SAFETY INSTRUCTIONS
2
Choose an installation location
8
Software Download and Installation
Please follow steps below to download and install monitoring software:
1. Go to the website http://www.Ablerex.com
2. Click Emily II software icon and then choose your required OS to down load the software.
3. Follow the on-screen instructions to install the software.
4. When your computer restarts, the monitoring software ※Software only for the model with communication port.
FRONT PANEL EXPLANATIONS
Symbol
LED
Description/function
Color
Tack switch for
N/A
Turn-on/Turn-off
Lit: Line mode
Dim: Abnormal input voltage
Green
and frequency in standby
mode
Flashing: Standby mode
Lit: Battery mode
Yellow
Flashing: Battery Low
Lit: System malfunction or
Red
abnormal
REAR PANEL EXPLANATIONS
SETUP
3
Connect the loads
Plug in the AC input cord to the Utility(Make sure the
voltage of Utility matches with the input
voltage window of the UPS)
※Plug the UPS into the wall outlet to charge the UPS for
over 8 hours before using the UPS.
Plug in the loads to output receptacles on the rear panel
of the UPS.
Caution:Do not connect a laser printer to the outlets.
These UPS outlets provide battery power to the
equipment when utility voltage is outside acceptable limits.
5
Connect
Computer
Interface Port
(Optional)
Connect the optional interface
cable to the USB interface
port on the back of the UPS.
Connect to the computer. See
software document for installation instruction.
GRs - 1000/1500/2000 - LCD
FRONT PANEL(OPTION))
4. RS-232 or USB port (option)
5. Modem/LAN Internet Protection (option)
6. Fan (only for GRs 1500/2000)
6
Turn ON/OFF the UPS
Turn on the UPS: Press the UPS
On/OFF Switch for approx. 3 seconds,
then the Buzzer sounds twice, the UPS
will be start-up.
Turn off the UPS: Press the UPS
On/OFF Switch for approx. 3 seconds,
then the Buzzer sounds twice, the UPS
will be shutdown.
1.Line mode
4. Battery capacity
2.Battery mode
5. Load level
3.AVR mode
6.Measurement
Target & Value
192321982025002
7.Fault
8.Tack switch for
Turn-on/Turn-off