AmeriFlow Water Systems Inc. ET6500 Panduan Pemilik - Halaman 8
Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Sistem Penyaringan Air AmeriFlow Water Systems Inc. ET6500. AmeriFlow Water Systems Inc. ET6500 17 halaman. Reverse osmosis systems
3. 3/8" black Drain Tube from Faucet Connect this tube to the black 3/8" drain clamp.
D in Figure 2 on page
TANT:
Do not leave excessive slack in drain tubing. Shorten tubing so that it flows
directly to the drain with no dips, loops, low spots, or kinks.
4. Post Filter Connection to Faucet Depending on the model, connect the 3/8" blue tube
from either the outlet side of the post-filter bowl or the outlet fitting from the 10" inline post-
filter cartridge to the 3/8" Push-In adapter fitting on the RO faucet.
5. RO Tank Connection Depending on the model, connect the 3/8" blue tube from either the
tee of the inlet side of the post-filter bowl or the tee of the inlet side of the 10" inline post-
filter cartridge to the Push-In ball valve on top of the RO storage tank.
STEP 7 SYSTEM START-UP PROCEDURES
Turn your sink cold water supply valve to the on position while leaving the Filter Pac/RO mod-
ule and RO tank ball valves in the off position (horizontal, which is perpendicular to the valve).
Check for leaks and adjust as necessary.
1. Slowly turn Filter Pac/RO module ball valve to the on position (blue valve vertical, which is
in line with the valve). As water enters the filter bowls and makes its way through the filters
to the membrane element you will hear air escaping through the drain. This is normal.
Open RO faucet on the sink until the water starts coming out. (Water flow will only be a
trickle and may take up to 20 minutes before water starts to come out of the faucet spout
on some units). Shut RO faucet off and check for leaks and adjust as necessary.
2. Open the tank ball valve by turning handle a ¼ turn toward the tubing. Let tank fill for 4 to
6 hours (if you are changing filters, your tank may already be full, so you would not need
to wait). Then turn on RO faucet and drain tank completely, (approx. 5 minutes). Shut RO
faucet off, allow tank to refill, and drain again in 4 to 6 hours. The RO system is shipped
with a food grade preservative and must be flushed out prior to use. DO NOT DRINK THE
RO WATER UNTIL TANK HAS BEEN DRAINED TWICE.
3. Shut RO faucet off and let system fill again. RO water is now ready for use.
IMPORTANT: Check carefully for small leaks every few hours for the first few days to assure
there are no leaks. It is wise on any RO system to inspect for leaks since the system sits
unseen underneath your sink and a small leak may not be detected without close inspection.
Check for leaks occasionally thereafter and make adjustments as necessary.
STEP 8 REFRIGERATOR ICEMAKER HOOK-UP
1. If there is not an ice-line from the RO to the refrigerator, you may choose to run an ice-line
so that your ice and water dispenser will have filtered water. If the distance from the refrig-
erator to the RO is more than 50', we recommend 3/8" polypropylene or polyethylene tub-
ing for best results. DO NOT USE COPPER. (Be sure you have the recommended water
pressure to your icemaker according to the refrigerator manufacturer's specifications.) 3/8"
tubing, a supplemental storage tank, more RO air pressure, or different usage patterns,
may be required to supply adequate pressure!
2. Connect tube
fitting
(not included)
is recommended to install a ball valve on the tube to the refrigerator for service and start
up purposes. Keep ball valve off until start up procedures are completed and RO tank is
completely full after the second tank draining.
IMPORTANT: Never turn on icemaker before RO tank is full of water to avoid damaging re-
frigerator solenoid. If your refrigerator has a water dispenser in the door, upon initial start-up
you will need to depress the water supply lever 2 to 3 minutes before the water will dispense.
STEP 9 RECOMMENDED FILTER SERVICE LIFE
The types of filters listed below vary depending on RO system style. The manufacturer
provides very high capacity carbon filters and replacement intervals are based on our filters.
7
07\15 RO Manual
6). Tighten firmly so tube will not pull out of drain clamp.
to appropriate refrigerator connection and to a plastic "T"
(not included)
spliced into the 3/8" blue tube between the post filter and faucet. It
(See
IMPOR-