Astor-Bannerman ABW6SP Panduan Pemilik & Panduan Instalasi - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Pemilik & Panduan Instalasi untuk Produk Pipa Astor-Bannerman ABW6SP. Astor-Bannerman ABW6SP 12 halaman. Height adjustable basin

Please Note: Due to the complexity of different building methods Astor
Bannerman do not supply installation fixings and anchors.
Important: The attachment rail is the main load bearing fixing; it is vital that it is secured
Measure 100mm up from the floor along the centre-line of the final position of the unit; using a
spirit level, draw a horizontal line at least 50mm long.
Place the attachment rail with the open lip upwards, on the line. With a pencil mark two of the
holes for the rail at least 50mm apart
Using a masonry bit, drill two 6mm full depth pilot holes at the marked positions and then open up
in order to accept the Anchors.
Fix the attachment rail, open lip
uppermost to the wall using suitable
fixings.
Ensure that the rail is level using a spirit
level (adjust to suit) and check that it is
secure.
With assistance, place the rise and fall unit
onto the wall ensuring that the two short
rails welded to the unit engage with the
one on the wall.
Ensure that the unit is level, then mark
the wall through the remaining three
attachment points, two on the lower
horizontal beam and one on the upper
horizontal beam
Remove the unit from the wall and at the
three marked positions drill three 6mm full-depth pilot holes.
Open the upper hole to accept a plastic wall plug.
Fit supporting Anchors in the two lower holes
Place the rise and fall unit back onto the wall-mounted rail. Fully fix the rise and fall unit to the
wall.
Ensure that the mains supply to the junction box on the wall is switched OFF.
Electrically connect the rise and fall unit to fused outlet behind the unit with the three-core cable
supplied.
Lower the arms and ensure the handset is fitted BEFORE switching the power on
correctly .
Page: 6
Centre of fixing holes
1200mm above Floor
Version : 11-04-016