Astra A5040 Panduan Pengguna - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Kompas Astra A5040. Astra A5040 14 halaman. Fluxgate compass gyro
1.3 Switch Inputs
Except for variants with suffix -S, two push-button switches are provided for calibrating the
compass in the field.
When the A5040 is viewed from the front face with the LED facing, then Switch 1 is on the right and
Switch 2 is on the left.
1
Switch 1:
2
Switch 2:
but at any azimuth. Pressing S2 sets the heading to zero and so can be done when the
whole installation is headed North.
3
Both together
calibration process to halt and restores the previously saved calibration values. (Equivalent
to sending the XCL command (see section 5.2)
1.4 Indicator light
A blue light indicates four states of the A5040 by the patterns of its flashing.
After the reset command, $PATC,IIHDG,0CV<CR><LF>, the A5040 is uncalibrated and the blue
indicator will show a VQF3 flash.
Note that the LED can be turned off and on by the DLED command – see section 5.
The indicator can show the following patterns:
VQF1 Fluxgate calibrated A single flash repeated
VQF2 Fault. A double flash repeated.
VQF3 Fluxgate not calibrated – the flashes are grouped in threes
VQF4 Fault. The flashes are grouped in fours.
S2
Fig 1
Start the auto-calibration process
Set reference NORTH heading. The A5040 must be mounted upright
Pressing both together for at least one second causes the auto-
S1
4