AMERITRON AL-811HD Buku Petunjuk - Halaman 6
Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Penguat AMERITRON AL-811HD. AMERITRON AL-811HD 16 halaman. Hf power linear amplifier
1. Connect the RF output of the transmitter or transceiver to
the RF IN connector on the rear of the AL-811HD with 50
ohm coax. Use any 50 ohm cable (RG-58 is fine) with PL-
259 plugs.
2. Connect the existing station antenna system to the RF OUT
connector on the AL-811HD with any 50 ohm coaxial cable
capable of carrying 650 watts.
3. Use shielded audio type cable with standard male phono
plugs to connect the RELAY jack on the AL-811HD to the
exciter's normally-open amplifier keying circuit.
keying circuit in the AL-811HD has a positive 12 VDC
open circuit and it provides 100mA of current when
connected to ground. The AL-811HD has an internal back-
pulse canceling diode across the relay coil.
FUSES
12A 120V
8A 240V
FAN
INTERCONNECTIONS
The
TO ANTENNA
OR ANTENNA TUNER
AMERITRON
AL-811HD
GND
A.C. POWER
PLUG
RF OUT
ALC
RELAY
4. Connect the shortest possible ground lead from a good
earth ground to the GND terminal. The best leads are solid
(instead of stranded or braided) copper. It is also best to
use a common ground point for all the equipment in the
station.
5. Use a shielded audio cable with standard male phono plugs
to connect the ALC out jack on the back of the amplifier to
the negative going ALC input jack on the exciter. Do not
connect this line until you have read and understand the
function of the ALC circuit. Exciters with output powers
below 70 watts do not normally require this connection. If
this jack is connected without adjusting the ALC control,
the exciter may not develop any drive power.
30/20
160 ALC
80
ADJ
ALC OUT
AUX
40
RELAY
15/17
RF OUT
RF IN
GND
TRANSMITTER OR
TRANSCEIVER
5
TO EARTH
GROUND