Introduction
Congratulations on your choice of the Ameritron ARI-500 Automatic Band
Switch for the Ameritron ALS-500M Amplifier. The ARI-500 is designed to
automatically select the correct frequency range on the amplifier by reading the
frequency or band data from the transceiver. This automatic switch is
compatible with most Icom, Yaesu, and Kenwood transceiver. Some other
radios may also be compatible.
Features
PWR:
Green LED indicates the amplifier and transceiver is connected correctly
LINK:
Red LED indicates information is being received from transceiver.
RADIO:
RJ-45 Jack for interfacing to the transceiver.
AMP A/B:
RJ-45 Jacks for interfacing to the ALS-500M
REMOTE A/B:
RJ-45 Jack for use with the optional ALS-500RC
Specifications
Receives power from the ALS-500M interface cables.
Dimensions 4.5" W x 1.5" H x 4.25 D
Weight
0.4 lbs
Installation
The ARI-500 connects to the Remote A/B jack on the front of the amplifier.
Two RJ-45 cables are supplied to connect jack A and B from the ARI-500
to the remote A/B on the ALS-500M.
1. Place the ARI in a suitable location.
2. Ensure the Amplifier switch is off and the frequency select switch is in
the Remote position.
3. Plug one of the patch cords into AMP A of the ARI-500. Route the
other end to the ALS-500M and connect to Remote A.
4. Plug the other patch cord into AMP B of the ARI-500. Route the other
end to the ALS-500M and connect to Remote B.
5. Set the ALS-500M's Frequency Select Switch to Remote Position.
Operating ALS-500RC with the ARI-500 (OPTIONAL)
Instruction Manual
3