DoorHan PCB-SH Manual Petunjuk Pemrograman - Halaman 10
Jelajahi secara online atau unduh pdf Manual Petunjuk Pemrograman untuk Pembuka Gerbang DoorHan PCB-SH. DoorHan PCB-SH 12 halaman. Control board
Juga untuk DoorHan PCB-SH: Manual Petunjuk Pemrograman (14 halaman), Manual Petunjuk Pemrograman (16 halaman)
2. OPERATOR PROGRAMMING
2.1. SELECTING THE OPERATING MODE
Selection of operating mode is performed with the P button. Number of the P button clicks corresponds to the selected oper-
ating mode number.
Operating mode
Program indicator flashes
1
one time
2
two times
3
three times
4
four times
5
five times
NOTE. The Open button operates under «open» — «close» — «open» logics in modes 4 and 5. It is recommended to
use pulse operation mode for door closing (modes 2, 4, 5) only if safety photocells are available. It is possible to use an
external radio receiver only in modes 4 or 5.
2.2. SETTING AUTOMATIC CLOSING TIME
Choose the operation mode 5 (automatic closing mode). Press and hold the P button, the Program indicator will light steadily
and go out in three seconds; after that release the P button. Wait for the desired time of automatic closing and press the P button
again (maximum automatic closing time is 5 min.).
NOTE. Automatic closing function operates only in mode 5. If automatic closing time was not set, then the door would
automatically close in 30 seconds.
3. TRANSMITTER PROGRAMMING
3.1. RECEIVER MEMORY CLEARING
After power supply is switched on, press and hold the transmitter programming button R for about 20 seconds. As 20 seconds
expire the Remote indicator will illuminate for a second to confirm that all the transmitters were erased from the memory.
3.2. RECORDING OF DOORHAN TRANSMITTERS IN THE RECEIVER
For transmitter recording press and hold the R button for 3 seconds. The Remote indicator will illuminate solid red. Release
the R button. Then press twice the button on the transmitter that you wish to control the operator. The Remote indicator will flash
red once to confirm that the receiver has learned the transmitter code.
NOTE. To record several transmitters repeat the code recording procedure for every transmitter. In case of receiver memory
overflow, the Remote indicator will flash three times (max. number of transmitters in the receiver's memory — 60 pcs.).
3.3. HOW TO DELETE A TRANSMITTER FROM RECEIVER MEMORY (FOR 1.1 SOFT ONLY)
To delete one particular transmitter, you must press and hold the R button, release it after the Remote indicator starts to blink
(about 13 seconds). Then press twice the button on the transmitter which you want to clear from the receiver memory. The Remote
indicator will go out.
3.4. REMOTE PROGRAMMING OF DOORHAN TRANSMITTERS
Perform items 1–4 within five-second interval:
1. Press and hold the 2 button of the programmed transmitter.
2. Holding the 2 button pressed, press and hold the 1 button.
3. Release all the buttons.
4. Press the programmed transmitter button, the receiver will switch to the transmitter programming mode (the Remote
indicator will steadily light).
10
Door opening
pulse pressing of Open button
pulse pressing of Open button
holding of Open button
pulse pressing of Open button
pulse pressing of Open button
OPERATOR PROGRAMMING
Table 3. Operating modes
Door closing
holding of Close button
pulse pressing of Close button
holding of Close button
pulse pressing of Close button
pulse pressing of Close button
Automatic closing
no
no
no
no
yes