5. ELECTRICAL CONNECTIONS
5.1 Control block specifications
Power supply of accessories
Maximal current of accessories
Working temperature range
Radio control frequency
5.2 Control block wiring diagram
WARNING! The cable wires must be protected from contact with any rough or sharp parts. All connections shall be made
only when power is off.
Photosells
LED3
NO
NC
5.3 Operator programming
1. OPERATOR CONTROL KEYS
1.
Radio code record button — "R"
2.
Display
3.
Setting selection buttons — "+", "–"
4.
Programming button — "P"
8
Parameters
Power supply
Operating logics
Connectors
Lamp turn-on time
Fuse type
Antenna
ANT
GND
IR
GND
24V
COM
NO
NC
COM NO NC
1
R
P
4
LAMP
24V DC
... ...
+
+
.. ... .....
Safety devices with normally
closed contacts (NC)
2
3
+
-

ELECTRICAL CONNECTIONS

Units
180-240 V/50-60 Hz
24 V DC
200 mA
–20...+55 °C
433,92 MHz
Automatic/Semi-automatic
Open button/Safety devices
3 min
Quick cutoff fuse, 230 V, 2.5 А
Black
BATTERY 24V
Observe the polarity!
Red
To lightening lamp
(built in operator housing)
Supply voltage of motor
12 V AC (after transformer)
PE
12V