DoorHan SLIDING-2100 Panduan Instalasi dan Pengoperasian - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pengoperasian untuk Pembuka Gerbang DoorHan SLIDING-2100. DoorHan SLIDING-2100 12 halaman. Drive
Juga untuk DoorHan SLIDING-2100: Panduan Instalasi dan Pengoperasian (16 halaman), Panduan Instalasi dan Pengoperasian (12 halaman)

DoorHan SLIDING-2100 Panduan Instalasi dan Pengoperasian
ContRoL BoARD

13.Control Board

Technical specifications
power supply
absorbed power
Motor max. load
accessories max. load
electric lock max. load
operating ambient temperature
protection fuses
Function logics
opening/closing time
pause time
Closing leaf delay
opening leaf delay
thrust force
terminal board inputs
terminal board outputs
Control board elements description
tF1
radio
sw1
F1
F2
tMr
aCl
FrC
photocells
signal lamp
Control board connectors description
~220 (n, l, pe)
Motor (n, l1, l2)
lamp
"-"
"+24V"
sw op
sw Cl
eMrg
ph op
ph Cl
ped
start
Control board led's description
Led
pWr
a
overloading of maximum current
B
overloading of fixed current
st
ped
ph1
ph2
stop
sw1
sw2
the condition of light-emitting diodes at the collars which are on the average position at rest, is allocated by a bold type.
8
I n s t a l l a t I o n a n d o p e r a t I n g M a n u a l o p e r a t o r s l I d I n g - 1 3 0 0 / 2 1 0 0
automatic / semi-automatic / "stepped" safety device / semi-automatic B/ dead-man C / "stepped" semi automatic
open / open free leaf / stop / opening safety devices / Closing safety devices / power supply + earth
Flashing lamp - Motors - 24 Vdc accessories power supply - 24 Vdc
purpose
power
start impulse
ped impulse
Close photocells
open photocells
stop command
Close limit switch
open limit switch
230 V~ ( +6% -10%) - 50 Hz
10 W
800 W
0,5 a
15 Va
-20 °C +55 °C
2 (see fig. 1)
programmable (from 0 to 120 s)
0, 10, 20, 30, 60, 120 s
0, 5, 10, 20 s
2 s (Can be disabled with the dip-switch)
dip-switch adjustable on 8 levels for each motor
power supply transformer
radio receiver speed connector
dip-switches
Fuse 2,5a
Fuse 0,5 a
Working time adjustment
autoclose pause adjustment
Force adjustment
1 pair of photocells
lamp
power supply
Motor connection
signal lamp connection
negative for acessories (24 V), 600 mА
positive for acessories (24 V), 600 mА
open limit switch (nC)
Close limit switch (nC)
emergency stop (nC)
open photocells (nC)
Close photocells (nC)
pedestrian opening impulse contact (dip2 is on) (no)
Full opening impulse contact (no)
on
Power supplied
overload current
overload current
activated
activated
disengaged
disengaged
inactive
disengaged
disengaged
off
not supplied
ok current
ok current
inactive
inactive
engaged
engaged
activated
engaged
engaged