5. LIMIT SWITCH ADJUSTMENT

5.1. Open position limit switch
1. Release the operator and fully open the gate leaf.
2. Unscrew the mounting screws of the open position limit switch (option).
3. Move the limit switch (option) along the guide until the switch is activated. SwOp LED on the control board will light when
the switch is activated.
4. Secure the switch (option).
5.2. Closed position limit switch
1. Close the gate leaf.
2. Unscrew the mounting screws of the closed position limit switch (option).
3. Move the limit switch (option) along the guide until the switch is activated. SwCl LED on the control board will light when
the switch is activated.
4. Secure the switch (option).

6. EMERGENCY RELEASE

Use emergency release to disengage the operator in case of a power failure.
Turn the release lever 90° to disengage the operator.
WARNING! The motor should be unlocked only when the power is off.
LIMIT SWITCH ADJUSTMENT
1
open position
limit switch
2
closed position
limit switch
9