5. Back panel
5-1. Form of Back panel & Using terminal stand
Make sure the terminal site and its use, and wire separately from a lot of nosing
wiring.
Press protruded button on the top of terminal stand, and insert it into the hole on the
lower part of it to the end.
Then, pull it gently to make its certainty.
(Suitable cable is 0.5-1. Linking cable must be brazing or used with 1 terminal)
① AC IN
: Main Power Supply Wiring Terminal
②
: Ground Terminal (In other way independent ground connection )
③ ZERO
: External ZERO Input Terminal
④ EXC+
: Sensor Supply Voltage + Connection Terminal
⑤ EXC-
: Sensor Supply Voltage - Connection Terminal
⑥ SIG+
: Sensor Output Signal + Connection Terminal
⑦ SIG-
: Sensor Output Signal - Connection Terminal
⑧ GND
: Sensor SHIELD Connection Terminal
⑨ S.CAL
: SHUNT CAL, ON/OFF S/W
⑩ 5/10V
: Sensor Supply Voltage 5V/10V choice S/W (ON : 5V, OFF : 10V)
⑪ Amplification Adjustment Switch
SW1 : 3.0mV/V
SW3 : 1.5mV/V
(Set with the number which gets near to maximum output value of sensor .)
SW2 : 2.0mV/V
SW4 : 1.0mV/V