Astria Inglenook CLP2 Panduan Petunjuk Pemasangan dan Pengoperasian - Halaman 8
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan dan Pengoperasian untuk Perapian Dalam Ruangan Astria Inglenook CLP2. Astria Inglenook CLP2 20 halaman. Custom series multi-sided wood burning fireplaces
WARNING: The opening in collar around chimney
at top of fireplace must not be obstructed. Never use
blown insulation to fill chimney enclosure.
12
/
"
3
8
Galvanized
Outer Pipe
Lanced
Ends
(Male)
PART NO.
Inglenook CRP2/CLP2
12-8DM
18-8DM
24-8DM
36-8DM
48-8DM
RT-8DM
RTL-8DM
RTT-8DM
RTTL-8DM
ET-8DM
ETL-8DM
ETO-8DM
ETLO-8DM
*Lineal Gain for Terminations is measured to
Flue Gas Outlet Height.
Figure 10 - Lineal Gain
USING CHIMNEY OFFSETS
To achieve desired offset, you may install combinations of 12", 18",
36" and 48" length of double wall pipe (see offset chart and Figure
11, this page and Figure 12, page 9).
Chimney weight above offset rests on return elbow. Straps must
be securely nailed to rafters or joists (see Figure 13, details A & B,
page 9).
Maximum length of pipe between supports (return elbow or chimney
support V12S-8DM) is 6' of angled run. Maximum of two 6' angled
run sections per chimney system.
8
VENTING INSTALLATION Continued
Hemmed
Ends
(Female)
8" Stainless
Inner Pipe
LINEAL GAIN
DESCRIPTION
GAIN
Fireplace
42"
Pipe Section
10
/
5
Pipe Section
16
/
5
Pipe Section
23
/
5
Pipe Section
34
/
5
Pipe Section
46
/
5
Round Termination
6
/
"*
7
8
Round Termination
7
/
"*
3
4
Round Termination
6
/
" to
7
8
with Slip Section
23
/
1
8
Round Termination
7
/
" to
3
4
with Slip Section
21
/
1
2
Square Chase
12"*
Termination
Square Chase with
7" to 15"*
Slip Section
Square Chase
12"*
with Mesh
Square Chase with
12" to
Mesh and Slip
21
/
1
2
Section
www.Astria.US.com
OFFSET
A
4
/
"
3
8
9
/
"
3
4
12
/
"
3
4
15"
18"
21
/
"
1
4
23
/
"
3
4
27
/
"
3
4
30"
33"
36"
38
/
"
1
4
41
/
"
1
4
45"
46
/
"
3
4
"
51"
8
"
53
/
"
1
8
4
"
8
56
/
"
1
4
"
8
59
/
"
1
"
4
8
61
/
"
3
4
64
/
"
3
4
68
/
"
1
4
"*
70"
74
/
"
"*
1
4
76
/
"
3
4
79
/
"
3
4
OFFSET CHART (22-50 FT. SYSTEM HEIGHT
"*
RISE
CHIMNEY LENGTH
B
48"
36"
24"
16
/
"
ELBOW SET ONLY
3
8
25
/
"
1
2
30
/
"
3
4
34
/
"
3
4
40"
46
/
"
1
1
4
49
/
"
1
4
56
/
"
1
3
4
60
/
"
1
3
4
66"
1
71"
1
75"
2
80
/
"
1
1
4
86
/
"
2
3
4
89
/
"
1
1
2
97"
1
1
101"
2
106
/
"
2
1
4
111
/
"
1
1
1
2
115
/
"
2
1
2
120
/
"
2
3
4
127"
1
2
130"
2
137
/
"
1
2
1
2
141
/
"
1
2
1
2
146
/
"
4
3
4
Screws
A
Figure 11 - Raise and Offset
18"
12"
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
)
B
126647-01A