DOOVAC MVO-100 Instruksi Instalasi - Halaman 9
Jelajahi secara online atau unduh pdf Instruksi Instalasi untuk Pompa Air DOOVAC MVO-100. DOOVAC MVO-100 11 halaman. Vacuum pump
Maintenance guide
1. The function of the oil circulation valve and pipe
The oil circulation type vacuum pump installs the exhaust filter to remove the smog on operation.
This pump is an equipment which circulates in an inlet with the liquid oil changed by the exhaust filter.
2. If the oil circulation system clogs by the foreign substances, the oil will discharge causing the rapid
consumption of the oil.
Therefore, it can cause the severe damage to the vacuum pump because the pump operates without
any oil left.
3. The oil circulation pipe cleaning method.
Unscrew the inlet pipe fastening bolt.
Important
: After cleaning, it will take some time until new oil fills up in the exhaust pipe.
When a test working after inspecting, please pour a little bit of oil in the exhaust
pipe and operate to check if the oil circulates. If working nicely, operate normally.
Please use the original circulation pipe and oil circulation valve (Float valve set).
Vacuum pump main inspection provision
oil circulation valve and pipe
If the oil is stagnant as the arrow points and the oil
and smog discharge through the exhaust pipe, it is
the oil circulation system problem.
oil circulation pipe
spraying the
compressed air
Remove the foreign substances as
spraying the compressed air to the end
of an oil circulation pipe.
LV.1~2
PF006
9/11