Maintenance Manual
1. To clean the air filter
A. Remove the screw on top. (As shown in Figure1)
B. Remove filter cover.
C. Take the filter out and clean it with clean water and dry it.
D. Put it back and secure the fixing plate with the screw in.
IMPORTANT: To open upper enclosure, please make sure
you have unplugged the power cord before opening.
2. To change the diaphragms
A. Remove the four screws around the aluminum upper housing,
and take the housing off. (As shown in figure 2)
B. Remove the four screws from the diaphragm housing. (As shown in figure 3)
C. Remove the u-nut in the center of diaphragm.
D. Take the diaphragm off its place.
E. Replace a new one by mounting the rubber studs
into their position.
F. Press the rim of the diaphragm into the ring.
G. Secure the magnet with a new u-nut and screw and put
the diaphragm housing back with the four screws on.
*Replacement part information.
Model Type
Air Force Pro™ 40
Part No: 746505
Air Force Pro™ 60
Part No: 746510
Air Force Pro™ 80
Part No: 746515
Maintenance Manual
Air Force Pro™ 40, 60, 80
Part No: 746505, 746510, 746515
Recommended once every six months
Figure 3
Diaphragm
service kit
Part No:
746520
Part No:
746525
Part No:
746525
10
10
Air filter
service kit
Part No:
746535
Part No:
746535
Part No:
746535
Figure 1
Figure 2