1.
Easy Open: When the door is fully closed and manually opened a few inches, it will automatically open the rest of the way.
2.
Adjustable Automatic Reversing: If the door is stalled during the closing cycle, it will automatically stop and reverse to the fully open position. Then
the door will close to the point of obstruction and drop to slow speed, looking for the obstruction. This cycle will occur 5 times until the obstruction is
removed. After the fifth cycle, the door will stop, requiring an activation signal or manual opening to re-start the system. If the door is stalled during
the opening cycle, it will automatically stop and reverse to the fully closed position. The door will remain closed until the next activation signal, at
which point it will open normally. Reversing forces should be adjusted in accordance with all applicable safety codes.
3.
Energy-wise (Optional): The energy-wise feature allows the customer to reduce the opening size. When the weatherwise switch is set to
"NARROW", the door will only open from 50% - 75% of the normal door opening.
(If energy-wise not used, door opens to 100% of opening)
4.
Beam Shut-Off: So the door is fully closed, the beam signal is disregarded so that it cannot be used to open the door. Once the door is activated,
the beam signal is allowed to re-open the door if either safety beam is interrupted during the closing cycle.
5.
4-Way Switch Operation:
When the 4-Position Switch is set to:
"OFF", easy open, interior and exterior activation will not open the door. The morning entry switch will open the door.
"1-WAY", only interior activation will open the door. Exterior activation will not open a closed door but will re-open a door in the closing cycle.
"2-WAY", interior and exterior activation will open the door.
"HOLD OPEN", the door will remain open.
If the 4-Position Switch is not used, Default = "1-WAY".
6.
Morning Entry (Optional): The morning entry feature allows outside entry using a keyswitch when the 4-way switch is in the OFF position. The
morning entry switch connects to the controller terminal block between COMMON and MORNING ENTRY (see Figure 2).
7.
Sidelite Safety (Optional): The sidelite safety feature slows the opening speed of the door when an obstruction is sensed in the sidelite area. The
sidelite safety sensor contacts connect to the controller terminal block between COMMON and SIDELITE SAFETY (see Figure 2).
1.
Do NOT try to use this operator on large, heavy doors without checking with the factory first.
2.
Do NOT connect any remote activating device to the door unless it is located within the "line of sight" of the door.
3.
Do NOT attempt to use a fuse larger than specified.
4.
Do NOT attempt to modify the factory wiring or connect any wiring into an existing electrical circuit or any other electrical device.
5.
Do make certain that the operator is connected to a dedicated 115 volt circuit from the main circuit breaker panel.
6.
Do make certain that the operator is properly grounded with a separate green wire.
7.
Do make certain that all connections are proper and secure before turning the power on.
8.
Do make certain that all wires are properly dressed and secured to prevent any interference.
9.
Do make certain that all safety labels and instruction decals relating to door operation are properly applied to the door before leaving the job.
10. Do verbally instruct the owner or person in charge of the proper operation of the door.
11. Do disconnect main power to the operator prior to servicing or cleaning.
12. Do instruct the owner or person in charge of his responsibility of inspecting the door for the following:
A.
Occasional damage
B.
Developing problems
C.
Minor preventative maintenance
D.
Who and where to call for service when required.
84657-084 REV. B
FEATURES
DO'S AND DON'TS
July 2003
Page 7 of 7