Doran 550 Series Panduan Operator - Halaman 10
Jelajahi secara online atau unduh pdf Panduan Operator untuk Timbangan Doran 550 Series. Doran 550 Series 14 halaman. Washdown bench scale
FnC 05
Zero: 0-9
(default 0)
FiL: 0-9
(default 0)
3db: 0-9
(default 5)
FnC 06
hoLd
FnC 08
uSEr
FnC 09
St
8
Filter Settings (non approval only)
Adjustments to offset environmental weighing interferences
Press TARE to enter sequence
1. ZEro "Weight Noise Threshold" eliminates minor weighing
noise when weight on scale is over 1/3 full capacity: 0=off;
1-9 = 1d to 9d threshold (weighing fluctuation below this
threshold is de-noised).
2. FiL "Weighing Sampling Period" sets time period for scale
to gather weighing information: 0 is shortest, fastest, & least
stable. 9 is longest, slowest, & most stable.
3. 3db "Weighing Bandwidth" sets frequency range for
gathering weighing information: Select 0-9. Default is 5. 0
is lowest, slowest, & most stable; 9 is highest, fastest, &
least stable.
Hold Function (non approval only)
0: Disabled (default)
1: Peak Hold Mode
2: Hold on stable weight, cleared by pressing any key
3: Hold on stable weight, cleared when weight removed
Two Weighing Units Setting
This setting allows the use of only two units (instead of four)
for quick unit switching.
0: Disabled (lb, kg, g, oz available)
1: kg (lb, kg available)
2: g (lb, g available)
3: oz (lb, oz available)
Tare on Demand (non approval only)
0: Disabled
1: Tare enabled when in motion