WARNING
!
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect media source and depressurize all media lines
connected to this product before installation, servicing, or
conversion.
• Operate within the manufacturer's specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, media and electrical
supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.
Introduction
Follow these instructions when installing, operating, or servicing
the product.
Application Limits
These products are intended for use in general purpose
compressed media systems only.
Operating Pressure:
Maximum Inlet Pressure 2068
Ambient Temperature Range:
WARNING
!
Product rupture can cause serious injury.
Do not connect regulator to bottled gas.
Do not exceed maximum primary pressure rating.
Symbols
Relieving Regulator
Adjustable
Installation
1. The regulator should be installed with reasonable
accessibility for service whenever possible - repair service
kits are available. Keep pipe and tubing lengths to a
minimum with inside clean and free of dirt and chips. Pipe
joint compound should be used sparingly and applied only
kPa
PSIG
bar
300
21.0
4°C to 49°C
(40°F to 120°F)
Non-Relieving Regulator
Adjustable
Installation & Service Instructions
CH-119
1/4", 3/8", 1/2", 3/4", 1", 1-1/4", 1-1/2"
General Purpose Regulators
to the male pipe - never into the female port. Do not use
PTFE tape to seal pipe joints - pieces have a tendency to
break off and lodge inside unit, possibly causing
malfunction.
2. Install regulator so that media flow is in the direction of
arrow. Installation must be upstream (high pressure) side
and as close to the devices it is to service (valve, cylinder,
tool, etc.). Mounting may be in any position.
3. Gauge ports are located on both sides of the regulator
body for your convenience. It is necessary to install a
gauge or pipe plugs into each port during installation.
4. For protection against rust, pipe scale, and other foreign
matter, install a filter on the upstream (high pressure) side
as close to the regulator as possible.
Operation
1. Before turning on the media source turn the T-handle
counterclockwise until compression is released from the
Control Spring. Then turn on media source and adjust
regulator to desired secondary pressure by turning T-handle
clockwise. This permits pressure to build up slowly, preventing
any unexpected operation of the valve, cylinders, tools, etc.,
attached to the line. Adjustment to desired secondary
pressure can be made only with primary pressure applied
to the regulator.
2. To decrease regulator pressure setting, always reset from a
pressure lower than the final setting desired. For example,
lowering the secondary pressure from 550 to 410 kPa (80
to 60 PSIG) is best accomplished by dropping the secondary
pressure to 350 kPa (50 PSIG), then adjusting upward to
410 kPa (60 PSIG). Tighten the Locking Nut on the T-handle
to lock the pressure setting.
Reduced Pressure Spring Ranges
"A" Range = 1 – 25 PSI (1/4", 3/8", 1/2" Only)
"B" Range = 2 – 60 PSI (1/4", 3/8", 1/2" Only)
"C" Range = 2 – 125 PSI (ALL)
"D" Range = 5 – 250 PSI (ALL)
WARNING
!
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other information from The Company, its
subsidiaries and authorized distributors provide product and/or system
options for further investigation by users having technical expertise. It
is important that you analyze all aspects of your application, including
consequences of any failure and review the information concerning
the product or systems in the current product catalog. Due to the
variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject to
change by The Company and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.