Akw M17 DigiPump Petunjuk Instalasi dan Perawatan Pengguna - Halaman 7

Jelajahi secara online atau unduh pdf Petunjuk Instalasi dan Perawatan Pengguna untuk Pompa Air Akw M17 DigiPump. Akw M17 DigiPump 20 halaman. Digipump

Fixing pump to surface
Fixing pump to surface
Check that the flow is in the required direction, reverse as required. Loosen the
5
pump head housing, rotate and fully tighten home.
The pipework to this high performance pump must be clamped down effectively,
AKW advise and recommend you clamp pipework either side of joints, junctions
or connections and at a maximum of 500mm between other supports.
Flow direction
Loosen
6
Remove shipping tapes from pump
inlet and outlet.
Refit the pump to the back plate.
Reconnect pump motor cable.
Fit the non-return valves as
7
shown. Fit the pump connectors
to the pump.
Screw both connectors into
place. No thread sealant
needed, firmly hand tighten
only.
Check that you have not
8
overtightened and distorted
the non-return valves before
connecting the pipework.
Refit the front cover.
Rotate to direction of flow
22mm
Connector
non-return valve
7
Fully tighten
Flow direction
Flow direction
22mm
Connector
non-return valve