AstroAI 202D Panduan Pengguna - Halaman 5

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Alat Ukur AstroAI 202D. AstroAI 202D 9 halaman. Auto ranging digital clamp meter

When this button is pushed, the display will show the last reading and "H" symbol will
appear until the DATA HOLD button is pushed again. Data holding will be cancelled
automatically when the function switch is changed/rotated.
8. MAX HOLD Button
When this button is pushed, the display will show the last Maximum reading and the
"M.H." symbol will appear until the MAX HOLD button is pushed again. Maximum hold
will be cancelled automatically when the function switch is changed/rotated.
9. VΩ Input Connect
High input for voltage, resistance, and continuity measurement that will accept banana
plugs. When measuring insulation resistance, use for accepted insulation tester unit VΩ
banana plugs.

SPECIFICATIONS

Accuracy is guaranteed for 1 year when recommended storage temperatures are met
(14°F~122°F (-10°C~50°C), less than 85% Relative Humidity).
DC VOLTAGE (Auto ranging)
Range
200mV
2V
20V
200V
600V
Input Impedance: 10MΩ
Overload Protection: 600V DC/AC rms
Max. Input voltage: 600V DC
AC CURRENT (Auto ranging)
Range
2A
20A
200A
400A
Measuring Voltage Drop: 200mV
Frequency Range: 40 - 200Hz
Resolution
0.1mV
1mV
10mV
100mV
1V
Resolution
1mA
10mA
100mA
1A
Accuracy
±(0.8% of rdg + 5dgts)
±(0.5% of rdg + 3dgts)
±(1.0% of rdg + 5dgts)
Accuracy
±(2.5% of rdg + 10dgts)
±(2.0% of rdg + 5dgts)