DOOR PREPARATION REFERENCE CHART
Fire Exit Hardware is to be installed on Fire Doors
bearing the marking "Fire Door to be equipped with Fire
Exit Hardware" Any retrofit or other field modification to
a Fire Rated opening can potentially impact the Fire
Rating of the opening.
OUTSIDE
RHR
LHR
INSIDE
DOOR CUT-OUTS
WOOD
CUT-OUT ON DEVICE
METAL
SIDE ONLY. 1³⁄8" DEEP
Consult template or
door preparation for:
- Metal door
- Wood Door
END CAP BRKT. - 2 HOLES
SURFACE MOUNT
METAL
#25 DRILL
#10-24 TAP
WOOD
¹/8" DRILL
PILOT 1" DEEP
*PREPARE HOLES AFTER LOCK SIDE
OF DEVICE IS MOUNTED AND HINGE
SIDE OF DEVICE IS LEVELED
TOP & BOTTOM LATCH PREPARATION
Prepare door bottom and top edge to accomodate required latch (see below) and vertical rods. Use the same backset (vertical centerline) used for the exit device center chassis.
It is recommended to install top and bottom latches using both pre-installed brackets as supplied.
Fire or Panic Exit Device
1⁵⁄8"
1⁹⁄32"
⁷⁄8"
Cut Out for Latchbolt 1¹⁄2"
4¹⁄2" height from
door top edge
LATCHES
METAL
#25 DRILL
#10-24 TAP
WOOD
¹/8" DRILL
PILOT 1" DEEP
LATCH RELEASE
PLUNGER HOLE
SEE PAGES 6 & 9
.
RHR shown (LHR opposite)
L C
SEX BOLTS
METAL
⁵⁄16" DRILL
(DEVICE SIDE)
¹³⁄32" DRILL
(OPPOSITE SIDE)
WOOD
¹³/32"
DRILL THRU
BOTTOM STRIKE
SEE PAGE 10
Both Brackets Installed
L C
Vertical
of Device
1⁵⁄8"
1⁹⁄32"
1" Dia.
For vertical
rod passage
4"
Cut Out for Brackets
⁹⁄32" deep
IMPORTANT:
• Use supplied templates for field installations.
TOP STRIKE
• Use door preparation documents for door/frame manufacturing.
SEE PAGE 9
• Door must be properly reinforced where the exit device chassis
and latches are mounted. The surface must be flush and flat
within ¹⁄16" (1.5 mm).
• Prepare the door and top and bottom door edges using the exit
device templates or door preparation and instructions.
• Prepare the exterior of door using the trim template or door
preparation and installation instructions.
• All threaded holes require a minimum metal material thickness
of 0.125" (3 mm).
• We recommend samples be used to verify preparation before
mass door or frame manufacturing.
• NOT RESPONSIBLE for any physical or property damage due to
incorrect / improper preparation or installation.
CENTER CASE - 2 HOLES
X
SURFACE MOUNT
L C
X
CENTER CASE
2 HOLES
SURFACE MOUNT
#25 DRILL
#10-24 TAP
¹/8" DRILL
PILOT 1" DEEP
1¹⁄2"
⁷⁄8"
Constant
⁷⁄8"
dimension
for all door
thicknesses.
4 / 12
SEX BOLTS
OR WITH TRIM
METAL
METAL
⁵⁄16" DRILL INSIDE
#7 DRILL
¹³/32" DRILL (FOR SEX BOLTS)
#¹/4"-20 TAP
¹/2" DRILL OUTSIDE (FOR TRIM)
WOOD
N/A
¹³/32" DRILL THRU (FOR SEX BOLTS)
¹/2" DRILL THRU (FOR TRIM)
SEE TRIM INSTALLATION INSTRUCTIONS,
TEMPLATES, OR DOOR PREPARATION
METAL
DOCUMENTS FOR DETAILS.
FOR DOOR PREPARATION REFERENCE ONLY.
WOOD
Verify that this is the latest version of this document.
We recommend samples be used to verify
preparation before door / frame manufacturing.
Panic Exit Device Only (optional)
One Bracket Installed
L C
Vertical
of Device
1⁵⁄8"
1⁹⁄32"
2"
Cut Out for Bracket
⁹⁄32" deep
1¹⁄2"
Constant
⁷⁄8"
dimension
for all door
thicknesses.