09. CUT DEVICE (IF REQUIRED)
Recommended minimum clearance between
door frame stop and device end (with cap
removed) is 1³⁄16"
Face of door stop
Hinge
Side
DOOR
1³⁄16"
Minimum
10. INSTALL MOUNTING BRACKET AND END CAP
Level Device
End Cap Bracket
1. Remove cover plate, insert end cap bracket into the push
bar rail assembly as shown.
2. Level exit device, then mark both mounting hole centers.
Drill and tap, then fasten bracket with the appropriate
mounting screws.
End Cap
Screws
J
End Cap
3. Insert cover plate, then slide anti-rattle clip into
position (minimum 2" from end) before fixing end
cap with supplied screws.
Center case aligned
with mounting holes.
End Cap
C
Bracket Screws
2" Minimum
Cover Plate
Anti-Rattle Clip
Remove
Anti-Rattle Clip
Tape
1. With anti-rattle clip removed, tape and mark area being cut.
2. Cut off device and deburr.
NOTE:
Device rail cut must be square, smooth and clean for proper fit
with end cap
11. INSTALL TOP LATCH AND ROD
Top Latch
Sex Bolts
F
Latch
Screws
Figure 1
1. Align top latch with top strike then install
top latch with two mounting screws (and
through-bolts for Fire). Adjust strike for
proper engagement. (Figure 1.)
2. Supplied rods are for 7 ft (84") door
height. if door height is less than 7 ft,
shorten the top rod by the difference
(Figure 2). Refer to page 10.
7 / 16
Cut off line
Cover Plate
(Flush to Push bar)
End Cap
Amount
H
to
Cut Off
Actual
Door
Opening
Height
Figure 2