[Details of Response]
"00" [CR]
Status : Power ON
Normal image is on the screen.
"80" [CR]
Status: Standby
When the status is Standby, Status Read Commands are always acceptable, but
Functional Execution Commands are not acceptable except POWER ON Command.
"40" [CR]
Status: Countdown in process
When "Display" in Setting Menu is ON and POWER ON is executed, it starts
Countdown.
When "Display" in Setting Menu is OFF, processing Countdown is not executed and the
status quickly moves to Power ON.
"20" [CR]
Status: Cooling Down in process
When the status is Power ON, and POWER OFF Command ("C01"[CR]) is executed, it
moves to Cooling Down status.
This status automatically moves to Standby after lamp turns off and the fan spin finishes
after about 90 seconds. The fan spin time depends on a model.
This function is used to cool down the lamps and other optical parts and is quite
important for projector's reliability.
During this time, Functional Execution Commands are invalid.
"10" [CR]
Status: Power Failure
When the power supply voltage inside the projector reaches abnormal status, the
projector is automatically turned off. The projector returns "10"[CR], which shows it
moves to Power OFF status due to power failure. Fan also stops unlike Cooling Down
status.
"28" [CR]
Status: Cooling Down in process due to Temperature Anomaly
When the inside temperature is out of the operating temperature, it automatically starts
Cooling Down. Response for this status is "28"[CR].
Even if the temperature decreases during this process, Cooling Down is executed.
"88" [CR]
Status: Coming back after temperature anomaly
When the status moves to Standby after Cooling Down due to temperature anomaly, it
returns "88" [CR].
This shows that the status turns to Standby because of abnormal temperature.