Canon LV-7575 Spesifikasi - Halaman 23

Jelajahi secara online atau unduh pdf Spesifikasi untuk Proyektor Canon LV-7575. Canon LV-7575 26 halaman. Basic serial command functional specifications
Juga untuk Canon LV-7575: Brosur & Spesifikasi (10 halaman)

LV-7575 Basic Serial Command Functional Specifications
• E "80" [CR]
Status: Standby
When the status is Standby, Status Read Commands are always accepted, but any
Functional Execution Commands are not accepted except for POWER ON command.
• E "40" [CR]
Status: Countdown in process
When "Display" in Setting Menu is set to ON, Countdown operation is started by execution
of POWER ON; while "Display" in Setting Menu is set to OFF, the status moves directly to
Power ON without Countdown operation.
• E "20" [CR]
Status: Cooling Down in process
When the status is Power ON, and then POWER OFF Command ("C01" [CR]) is executed,
it moves to Cooling Down status.
When lamp turns off and about 90 seconds of fan spinning finishes, the above status
automatically moves to Standby (The fan spinning time depends on models.)
This function is intended to cool down lamps and other optical parts, and is quite important
for projector's reliability. During this time, any Functional Execution Command is invalid.
• E "10" [CR]
Status: Power Failure
When the power supply voltage inside the projector reaches abnormal status, the projector
is automatically turned off. The projector returns "10" [CR], which indicates it enters Power
OFF status due to Power Failure.
In this case Fan also stops unlike Cooling Down status.
• E "28" [CR]
Status: Cooling Down in process due to Abnormal Temperature
When the inside temperature rises abnormally high, it automatically starts Cooling Down
operation. The projector returns "28" [CR].
Even if the temperature goes down during this process, the given Cooling Down process is
conducted.
• E "88" [CR]
Status: Standby after Cooling Down due to Abnormal Temperature
When the status becomes Standby after the temperature goes down by Cooling Down
operation invoked due to Abnormal Temperature, the projector returns "88" [CR]. This
indicates Abnormal Temperature caused turning to Standby status.
This status continues until the next operation is started; when Power On is executed, the
23/26