dafi IPX4 Panduan Petunjuk Pengoperasian - Halaman 7
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Pemanas Air dafi IPX4. dafi IPX4 13 halaman. Electric a flow heater with an open outlet water
Juga untuk dafi IPX4: Instruksi Untuk Pemasangan dan Penggunaan (12 halaman)
the back of the heater (fig. 13). Then, open the shut-off va-
lve upstream the heater and the hot water valve on the tap
and let out the quantity of water that is necessary to deaerate
the heater. The installation of the DAFI heater in this system
fig 9
enables its installation next to the shower enclosure or under
the wash basin or sink with the three-way faucet. It also ma-
kes the supply of the heated water to several receipt points
possible. The heater with the connector may operate in any
position.
It is required to close the shut-off valve before the disassem-
fig 10
bly of the heater or before each operational break longer than
12 hours
7.3 Installation of the heater to the three-way
a
faucet
Use only the DAFI heater with the protection degree
of IPX 4 for this type of installation.
The DAFI shut-off valve must be installed directly at
the inlet of water to the heater.
fig 11
Before the installation of the heater, while turning on
the DAFI shut-off valve, let the necessary water flow
b
through it in order to remove the contamination and
air which are present inside the water system. Con-
nect the DAFI heater, using the reducing nipples and
hoses for the shut-off valve and the tap. Then, open
the valve that shuts off the water supply to the heater
and the hot water valve on the tap and let out the wa-
ter quantity that is necessary to deaerate the heater.
cold
water
hot
8. Operation
water
NOTE!
Before connecting the heater to the wiring system,
deaerate the heater (see section 7.1.h, 7.2 and 7.3).
If the air flows out instead of water during the use,
close the water supply immediately and disconnect
fig 12
the power supply for the heater. Power supply may
be switched on again after the heater is deaerated.
Do not switch on the heater, if it is likely that the
water in the heater is frozen (as mentioned above
in warning from section 6.1).
The contamination of the aerator may cause:
- reduction or total disappearance of water outflow,
fig 13
- excessive heating of water or such decrease in
the water outflow which prevents the heater from
being switched on.