6. Parameterization and configuration

6.1. Parameterization

Parameterization refers to transfer of information required by the slave for process data exchange. The
information comprises Profibus-specific data (octet 1 to 6) as well as user-specific information. User-
specific information can be entered via an input window during the project processing phase.
The data received from master are compared by the slave with the data it has stored. However, the slave
will only inform the master of the result in the diagnosis request after configuration.
Parameter description for the parameterization function (Set_Prm)
Parameter
Station status
Response monitoring time
Min. Station Delay
Responder (tsdr)
Ident_No.
Group_Ident_No.
Operating parameter
Parameters of the
inclination sensor
Resolution
Baumer_GNAMG_Profibus_MA_EN
07.18
Octet Nr.
Significance
Definition of profibus-specific data
Sync mode/freeze mode active
1
Response monitoring active
Master assigned
Recognition of master failure, master must respond within
2 to 3
this time
Minimum time the slave has to wait until it is allowed to
4
respond to a master's request
Device identifier, unique for each device type, defined and
5 to 6
reserved by the PNO
7
Profibus-specific data
8
Profibus-specific data
Definition of application-specific data
Inversion of the inclination angles of the axis
9
Scaling function
Standard diagnosis/ extended diagnosis
Resolution
10
Parameter location for four optional resolutions