Parameter Response Block:
Request Header
Parameter Value
(*) encoder information at Read Response.
Encoder supports single parameter access.
Maximum parameter access length: 240 bytes.
6.4. Supported parameters
6.4.1.
PROFIdrive Parameters
P922: Telegram Type
P925: Tolerated Life sign Failures
P964: Device ID
P965: Profile ID
P971: Store Data
P974: Base Mode Parameter
P975: Encoder Object ID
P979: Sensor Format
P980: Number List of defined Parameters
6.4.2.
Interface Parameters
P61000: Name of Station
P61001: IP of Station
P61002: MAC of Station
P61003: Default Gateway of Station
P61004: Subnet Mask of Station
6.4.3.
Encoder Parameters
P65000: Preset Value
P65001: Operating Status / Parameters
6.4.4.
Parameter 922: Telegram Type
.
Read: Parameter reads the configured telegram type.
Type 100:
Type 101:
Type 102:
Type 81:
Type 82:
Type 83:
Parameter
Type
Data type
Value range
Data: 922[0]
Baumer_BUDE-PROFINET_MA_EN.docx
14.06.2016 / bja
Response Reference
Response ID
DO-ID
No of Parameters
Format / Data Type
Number of values
values read
manufacturer-specific telegram, 32bit I/O
manufacturer-specific telegram, 32bit I/O + 16bit speed
manufacturer-specific telegram, 32bit I/O + 32bit speed
PROFIdrive telegram 81
PROFIdrive telegram 82
PROFIdrive telegram 83
922
Read only
unsigned int (0x06)
100-102 (0x0064 – 0x0066), 81-83 (0x0051 – 0x0053)
Telegram type
32/41
BYTE
mirrored
see Request
BYTE
mirrored
see Request
BYTE
0x00
(Base Mode)
BYTE
0x01
Single-Parameter Access
BYTE
(*)
see parameter description.
BYTE
(*)
see parameter description.
BYTE
(*)
see parameter description.
www.baumer.com