13.2

Electrical data

HS35 - general parameters
Voltage supply
Reverse polarity protection Yes
Sensing method
Interference immunity
Emitted interference
Approvals
HS35F
Consumption w/o load ≤40 mA (24 VDC)
Resolution (steps/turn) 1024...80000
Output frequency
Output signals
Output circuit
HS35P
Consumption w/o load ≤50 mA (24 VDC)
Resolution (steps/turn) 1...8192
Output frequency
Output signals
Output circuit
Programmable
parameters
Baumer_HS35_II_DE-EN_1706.indd
4.75...30 VDC
Optical
DIN EN 61000-6-2
DIN EN 61000-6-4
UL approval / file no. E240061, ROHS compliant EU
guideline 2011/65/EG, CE conform
≤130 mA (4.75 VDC) + output load, max. 250 mA
≤300 kHz (TTL), ≤160 kHz (HTL), ≤160 kHz (OC)
A, B, Z
A, B, Z + complement,
½ cycle index gated with negative B channel
Linedriver (TTL, 7272), Vout = 5 V, short-circuit proof
Push-pull (HTL, 7272), Vout = Vin, short-circuit proof
Open Collector (OC, 7273), Vout = Vin, short-circuit proof
≤180 mA (5 VDC) + output load, max. 250 mA
≤300 kHz (TTL), ≤160 kHz (HTL), ≤160 kHz (OC)
A, B, Z
A, B, Z + complement,
½ cycle index gated with negative B channel
Linedriver (TTL, 7272), Vout = 5 V, short-circuit proof
Push-pull (HTL, 7272), Vout = Vin, short-circuit proof
Open Collector (OC, 7273), Vout = Vin, short-circuit proof
Output resolution in increments of one (can be different
for A and B)
Output signal level (TTL or HTL)
Zero pulse width and position
Rotational direction CW/CCW
Technical data