Baumer HUBNER BERLIN EtherCAT PMG 10 Panduan Petunjuk Pemasangan dan Pengoperasian - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan dan Pengoperasian untuk Konverter Media Baumer HUBNER BERLIN EtherCAT PMG 10. Baumer HUBNER BERLIN EtherCAT PMG 10 24 halaman. Absolute encoder with magnetic sensing

MOUNTING / MOUNTING THE SPRING DISK COUPLING TO THE ENCODER
4.

MOUNTING

4.1
Mounting the spring disk coupling to the encoder
We recommend using the Baumer Hübner spring disk coupling K 35, see
9, available as accessory� When other couplings are used pay attention to manufactu-
rer's notes�
)
4.2
Mounting to drive shaft
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error�
High runout of the drive shaft can cause vibrations, which can shorten the lifetime of
the encoder�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
7/21
2�5 mm
8
M
= 100 Ncm
t
7
10 mm
6
MB255EN - 11173976, 16A1, Baumer_PMG10-EtherCAT_II_EN
section 4.4, page