Baumer HUBNER BERLIN HMG 10-EtherCAT Panduan Petunjuk Pemasangan dan Pengoperasian - Halaman 17
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan dan Pengoperasian untuk Konverter Media Baumer HUBNER BERLIN HMG 10-EtherCAT. Baumer HUBNER BERLIN HMG 10-EtherCAT 32 halaman. Absolute encoder with magnetic sensing
)
5.1.2
Terminal assignment
Use connecting cable and connector exclusively in accordance to the
EtherCAT directive�
5.1.2.1
Bus connecting box EtherCAT [A]
5.1.2.2
Connector M12 [C] „Voltage supply" (male, 4-pin, A-coded)
4
1
5.1.2.3
Connector M12 [D] and [E] „Data transmission" (female, 4-pin, D-coded)
3
2
MB254EN - 11173973, 16A1, Baumer_HMG10-EtherCAT_II_EN
[ C ]
MALE
CONNECTION DESCRIPTION
3
1
2
3
2
4
FEMALE CONNECTION DESCRIPTION
4
1
2
3
4
1
ELECTRICAL CONNECTION / ETHERCAT
Bus connecting box
EtherCAT [ A ]
[ D ] [ E ]
UB
Voltage supply 10���30 VDC
-
Do not use
GND
Ground for UB
-
Do not use
TxD+
Transmission data+
RxD+
Receiving data+
TxD-
Transmission data-
RxD-
Receiving data-
14/29