Technical data - mechanical design

• Sensor head:
• Size (flange):
• Shaft type:
• Axial tolerance:
• Radial tolerance:
• Protection DIN EN 60529:
• Operating temperature:
• Operating speed:
• Materials:
• Resistance:
• Accuracy of magnetic measure:
• Connection:
MB200T2 - 11121631
Baumer_MHGE100-T2_DE_EN_202210_MI_11121631 (22A1)
Standard signal processing
ø99.9 mm
ø16...80 mm (through hollow shaft)
(as ordered)
±3 mm (wheel/head)
0.1...2.2 mm (wheel/head)
IP67 (head)
IP68 (wheel)
-40...+100 °C
≤8000 rpm
Housing sensing head: aluminium alloy
Wheel: stainless steel (1.4104, option DNV: 1.4313)
IEC 60068-2-6
Vibration 30 g, 55-2000 Hz
IEC 60068-2-27
Shock 300 g, 2 ms
±300 "
Flange connector M23, 12-pin