Baumer Hubner Berlin microGen PMG10 Panduan Pengoperasian - Halaman 14

Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Konverter Media Baumer Hubner Berlin microGen PMG10. Baumer Hubner Berlin microGen PMG10 44 halaman. Absolute encoder
Juga untuk Baumer Hubner Berlin microGen PMG10: Panduan Pengoperasian (40 halaman), Panduan Pengoperasian (40 halaman)

5
|
Installation
Ill. 4: Installing encoder, mounting device and coupling
1
Drive shaft
3
Attachment device (customized)
Tools
2.5 mm
n
n
Instruction:
a) Prior to installation, check the drive runout error and dimensions.
b) Mount the encoder in a way ensuring the electrical connection is protected against direct
water ingress.
c) Apply grease onto the drive shaft.
d) Mount the attachment device (customer-specific) to the drive using the fastening screws.
e) Push coupling onto the encoder shaft and tighten to the specified torque.
K35 permitted tightening torque:
Mt = 1 ±10 % Nm (plastic side)
Mt = 1.3 ±10 % Nm (metal side)
f) Mount the encoder using suitable screws, e.g. M6x16 mm (ISO 4017) onto the B10 flange of
drive or attachment device (customer-specific).
g) Fasten the coupling on the drive shaft.
K35 Permitted tightening torque:
Mt = 1 ±10 % Nm (plastic side)
Mt = 1.3 ±10 % Nm (metal side)
Observe the remarks in the data sheet and the coupling assembly instructions.
14
1
2
10 mm
Operating Manual
3
4
2
Mounting screw M6x16 mm for attach-
ment device (ISO 4017)
4
Coupling
Baumer Hübner
PMG10 & PMG10P DeviceNet | V1