Baumer Hubner Berlin microGen PMG10 EtherCAT Panduan Pengoperasian - Halaman 14

Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Konverter Media Baumer Hubner Berlin microGen PMG10 EtherCAT. Baumer Hubner Berlin microGen PMG10 EtherCAT 36 halaman. Absolute encoder

5
|
Installation
5.2

Mounting with base B3

5.2.1

Attach coupling onto encoder shaft

INFO
Baumer recommends to use the Baumer Hübner K 35 spring disc coupling to connect the rotary
encoder and the drive shaft of the following device. The Baumer Hübner K 35 spring disc cou-
pling can be pushed onto the drive shaft without axial pressure.
1
Ill. 5: Attach coupling onto encoder shaft
1
Coupling
Tools
2.5 mm
n
Instruction:
a) Mount the coupling on the encoder shaft , observe the related mounting instructions.
b) When using the K 35 spring washer of Baumer Hübner, consider the maximum permitted
tolerances for mounting errors.
c) Fasten the coupling at the specified torque (K 35: Mt = 1 Nm (plastic side), Mt = 1.3 ± 10%
Nm (metal side)). Observe the remarks in the spring washer assembly instructions.
Also see about this
2 Maximum permitted tolerances for mounting errors when using the Baumer Hübner K 35
spring washer [} 17]
14
Operating Manual
Baumer Hübner
PMG10 & PMG10P EtherCAT | V1