TECHNICAL DATA

8.
TECHNICAL DATA
8.1
Technical data - electrical ratings
Voltage supply
Short-circuit proof
Consumption w/o load
Initializing time
Interface
Function
Steps per turn
Number of turns
Additional outputs
Sensing method
Code
Code sequence
Input signals
Interference immunity
Emitted interference
Diagnostic functions
Status indicator
Approvals
8.2
Technical data - electrical ratings (speed switch)
Interface
Switching accuracy
Switching outputs
Output switching capacity
Switching delay time
* Depending on the version
29/33
4,75���30 VDC
yes
≤100 mA (SSI)
≤500 ms after power on
SSI
Multiturn
1048576 / 20 Bit
1048576 / 20 Bit
Square-wave HTL
Square-wave TTL (RS422)
Magnetic
Gray (default) or binary
CW/CCW programmable
CW default
SSI clock, PRESET, rotating direction
EN 61000-6-2
EN 61000-6-3
Self-diagnosis
4 LEDs integrated in device back side
CE
RS485
±2 % (or Digit)
1 output
(Open-Collector* or Solid State Relay*)
30 VDC; ≤100 mA
≤20 ms