6
|
Electrical installation
6.3

Output signals additional incremental output (optional)

At positive rotating direction
A+
A-
B+
B-
R+
Zero pulse+
R-
Zero pulse-
Ill. 9: Output signals with positive direction of rotation (zero pulse R+ and R- are only available at additional
output II)
6.4

Switching level additional output incremental (optional)

Switching level
High/Low
Transmission length
Output frequency
I
The TTL/HTL output (Vin = Vout) at the additional output II incremental is galvanically iso-
lated and requires a separate voltage supply.
Tab. 1: Switching level additional output incremental (optional)
6.5

Programming interface (only for programmable variant)

Encoder parameters such as resolution singleturn and/or multiturn (SSI), binary or gray code
(SSI), additional output 1 and 2, switch-off and switch-on speeds can be changed and read out
via connection SA and SB. The Z-PA.SDL.1 WLAN adapter can be used to access the encoder
via web browser.
22
90°
TTL/RS422
≥ 2,5 V / ≤ 0,5 V
≤ 550 m bei 100 kHz
≤ 600 kHz
Operating Manual
Baumer Hübner
TTL/HTL (Vin = Vout)
≥ 2,5 V / ≤ 0,5 V (TTL)
n
≥ Ub − 3 V / ≤ 1,5 V (HTL)
n
≤ 550 m bei 100 kHz (TTL)
n
≤ 350 m bei 100 kHz (HTL)
n
≤ 600 kHz (TTL)
n
≤ 350 kHz (HTL)
n
PMG10 & PMG10P SSI | V1