MOUNTING / DRIVE SIDE MOUNTING OF THE TORqUE ARM
4.4
Drive side mounting of the torque arm
)
Service life restrictions and angle error by runouts
A play of just ±0�03 mm, results in a runout of the device of 0�06 mm� That may lead
to a large angle error, see
» Mount the torque arm without play�
11/27
section 4.5, page
12�
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN