8.
TECHNICAL DATA
8.1
Technical data - electrical ratings
Voltage supply
Short-circuit proof
Consumption w/o load
Initializing time
Interface
Transmission rate
Device address
Steps per turn
Number of turns
Additional outputs
Sensing method
Interference immunity
Emitted interference
Programming interface
Programmable parameters
Diagnostic function
Status indicator
Approvals
8.2
Technical data - electrical ratings (speed switches)
Switching accuracy
Switching outputs
Output switching capacity
Switching delay time
* Depending on version
Only HMG10P
6)
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN
10���30 VDC
yes
≤200 mA
≤500 ms after power on
PROFINET
100 MBaud
Automatic address designation
8192 / 13 bit
65536 / 16 bit
Square-wave TTL/HTL, TTL/RS422
Magnetic
EN 61000-6-2
EN 61000-6-3
RS485 (≤600 m)
6)
Bus system: see bus features in
Additional output (number of pulses)
switch-off and switch-on speeds
Position or parameter error
DUO-LED und LEDs link/activity in
bus connecting box
4 LEDs in device back side
CE, UL approval / E256710
±2 % (or 1 Digit)
1 output
(Open collector* or solid state relay*)
30 VDC; ≤100 mA
≤20 ms
TECHNICAL DATA
section 5.1.1
,
6)
6)