Baumer HUBNER BERLIN Proibus DP HMG 10 Panduan Petunjuk Pemasangan dan Pengoperasian - Halaman 14
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan dan Pengoperasian untuk Konverter Media Baumer HUBNER BERLIN Proibus DP HMG 10. Baumer HUBNER BERLIN Proibus DP HMG 10 32 halaman. Absolute encoder with magnetic sensing
MOUNTING / DRIVE SIDE MOUNTING OF THE TORqUE ARM
)
4.4
Drive side mounting of the torque arm
Lifetime restrictions and angle error of the encoder
A play of just ±0.03 mm, results in concentricity error of the encoder of 0.06 mm.
That may lead to a large angle error, see
» Mount the torque arm without play.
11/29
section 4.5, page
MB246EN - 11171695, 16A3, Baumer_HMG10-ProibusDP_II_EN
12�