Baumer HUBNER BERLIN Proibus DP HMG 10 Panduan Petunjuk Pemasangan dan Pengoperasian - Halaman 21

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan dan Pengoperasian untuk Konverter Media Baumer HUBNER BERLIN Proibus DP HMG 10. Baumer HUBNER BERLIN Proibus DP HMG 10 32 halaman. Absolute encoder with magnetic sensing

Baumer HUBNER BERLIN Proibus DP HMG 10 Panduan Petunjuk Pemasangan dan Pengoperasian
ELECTRICAL CONNECTION / SPEED SWITCH AND ADDITIONAL OUTPUT INCREMENTAL
5.2.3

LED function displays

LED
INC1
INC2
(additional output
incremental)
Status
Speed
5.2.4

Speed switch - Switching characteristics

Event
During initialisation
After initialisation and
speed ≤ -ns (off)
-ns (off) < speed ≤ -ns (on)
-ns (on) < speed < +ns (on)
+ns (on) ≤ speed < +ns (off)
+ns (off) ≤ speed
High resistance
Resistance between
SP+ and SP-
Low resistance
n
+ns (on) = Activation speed at shaft rotation in positive rotating direction*
+ns (off) = Deactivation speed at shaft rotation in positive rotating direction*
-ns (on) = Activation speed at shaft rotation in negative rotating direction*
-ns (off) = Deactivation at shaft rotation in negative rotating direction*
* See
section 6, page 21
MB246EN - 11171695, 16A3, Baumer_HMG10-ProibusDP_II_EN
red
Without function
Undervoltage
Overload
Over-temperature
Internal error
Speed higher switching speed Speed lower switching speed
(overspeed)
-n
-ns (off)
= Speed
State of the speed switch output
High resistance (overspeed)
High resistance (overspeed)
State unchanged
Low resistance (no overspeed) after initialisation
if the encoder is rotating between the switching
range during initialisation.
Low resistance (no overspeed)
State unchanged
Low resistance (no overspeed) after initialisation
if the encoder is rotating between the switching
range during initialisation.
High resistance (overspeed)
-ns (on)
0
green
Without function
OK
OK
+ns (on)
+ns (off)
+n
18/29