Baumer Hubner EtherNet/IP HMG10 Panduan Pengoperasian - Halaman 36
Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Konverter Media Baumer Hubner EtherNet/IP HMG10. Baumer Hubner EtherNet/IP HMG10 44 halaman.
7
|
Disassembly
Tool
5 mm
n
1,6×8 mm
n
n
20 mm
n
Instruction:
a) Disconnect the electrical connection to the encoder using the plug-in terminal boxes and
contacts.
b) Remove the cover at rear.
c) Unscrew the cheese-head screw and secure at the hollow shaft using a wrench.
d) Loosen the self-locking nut on the torque arm.
e) Loosen the cheese-head screw at ground strap.
7.1.2
Threaded pin to secure at blind hollow shaft
1
Threaded pin M6x10 mm (ISO 7436)
Tool
0,8×4 mm
n
Instruction:
w Flush attachment of the threaded pin will protect the inside thread of the drive shaft.
36
10 mm, 17 mm
Operating Manual
1
HMG10 & HMG10P EtherNet/IP | V1, T1
Baumer Hübner