4
Terminal assignment and commissioning
Electrical connection
4.1
Terminal assignment 1-dimensional
4.1.1
M12 flange connector, 8-pin
Pin
Assignment
1
+Vs
2
GND
3
OUT
4
d.u.
5
Teach
6
d.u.
7
d.u.
8
A_GND
Terminals with the same designation are internally hardwired and identical in their functions. Maximum load
applied on Vs-Vs / GND-GND is 1 A each.
Cable wires
Wire
Assignment
white
+Vs
brown
GND
green
OUT
yellow
d.u.
grey
Teach
pink
d.u.
blue
d.u.
red
A_GND
Wires with the same designation are internally hardwired and identical in their functions. Maximum load
applied on Vs-Vs / GND-GND is 1 A each.
Terminal assignment 2-dimensional
4.1.2
M12 flange connector, 8-pin
Pin
Assignment
1
+Vs
2
GND
3
OUT_X
4
OUT_Y
5
Teach
6
d.u.
7
d.u.
8
A_GND
Baumer_GIM500R_Analog_MA_EN.docx
11.04.18
Description
Voltage supply
Ground connection relating to +Vs
output
Do not use
Teach input
Do not use
Do not use
Ground connection related to analog
Description
Voltage supply
Ground connection relating to +Vs
Output
Do not use
Teach input
Do not use
Do not use
Ground connection related to analog
Description
Voltage supply
Ground connection relating to +Vs
Output
Output
Teach input
Do not use
Do not use
Ground connection related to analog
18/20
M12 connector, A-coded,
male contacts
M12 connector, A-coded,
male contacts
Baumer IVO GmbH & Co. KG