Baumer OM20 Panduan Pengoperasian - Halaman 15

Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Alat Ukur Baumer OM20. Baumer OM20 48 halaman. Laser distance sensors

Baumer OM20 Panduan Pengoperasian
Baumer
Process data name
Bit 16 to 47: Measurement value
(MDC)
I
MDC = Measurement Data Channel
Parameters
Parameters are acyclic data (transmission occurs as needed). The following parameters are
available for the sensor:
Filters for smoothing the signal characteristics
n
Triggers for recording the measured value
n
Processing of invalid measured values
n
Switching points
n
Polarity (output level of the switching output)
n
Hysteresis
n
Zero position
n
Limits of the measurement range
n
Limits of the analog measurement field
n
Output & LED (alarm/switching output)
n
Configuration of the Teach button
n
Diagnostic data
The diagnostic data is used for monitoring the status of the device. The following diagnostic
data is available for the sensor:
Measurement rate
n
Reply delay
n
Exposure reserve
n
Signal quality
n
Device status
n
Operating time
n
Histogram function
n
A detailed description of the IO-Link functions is found in the operating manual.
For a detailed description of the IO-Link functions, see
tion of the diagnostic data, see
OM20/OM30 | V1
Description
Example:
n
▪ Measurement value (MDC): 1000
▪ Scale: -6
▪ Unit: m
▪ Therefore: 1000 × 10
Measured value
n
Diagnostic data
[} 37].
Operating Manual
-6
× m = 1000 µm
Functions
[} 22]. For a detailed descrip-
Description
|
3