Figure 12 ►
Temperature measure-
ment points of Baumer 
SXC cameras.
20

Environmental Requirements

6.5.

6.5.1. Temperature and Humidity Range

Storage temperature
Operating temperature*
Housing temperature
**)***)
* For environmental temperatures ranging from (value A) to (value B), please pay atten-
tion to the max. housing temperature. The values are listed in the table below:
Caution
Provide adequate dissipation of heat, to ensure that the temperature does
not exceed +60°C (+140°F).
The surface of the camera may be hot during operation and immediately 
after use. Be careful when handling the camera and avoid contact over a 
longer period.
Storage and Operating Humidity

6.5.2. Heat Transmission

It is very important to provide adequate dissipation of heat, to ensure that the housing 
temperature does not reach or exceed +60°C (+140°F). As there are numerous possibili-
ties for installation, Baumer do not specifiy a specific method for proper heat dissipation, 
but suggest the following principles:
operate the cameras only in mounted condition
mounting in combination with forced convection may provide proper heat dissipation
*)
Please refer to the respective data sheet.
**) 
Measured at temperature measurement point (T).
***) 
Housing temperature is limited by sensor specifications.
*)
Temperature
-10°C ... +70°C ( +14°F ... +158°F)
+5°C ... +60°C (+41°F ... +140°F)
max. +60°C (+140°F)
Humidity
T
10% ... 90%
Non-condensing