Baumer SXC80 Panduan Pengguna - Halaman 35

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Kamera Digital Baumer SXC80. Baumer SXC80 48 halaman. Sxc series cameralink cameras with truesense imaging sensors
Juga untuk Baumer SXC80: Panduan Memulai Cepat (2 halaman)

Baumer SXC80 Panduan Pengguna

8.5.2. Trigger Input

Trigger signals are used to synchronize the camera exposure and a machine cycle or, in 
case of a software trigger, to take images at predefined time intervals.
A
B
Different trigger sources can be used here.

8.5.3. Trigger Source

Each trigger source has to be activated separately. When the trigger mode is activated, 
the hardware trigger is activated by default.
Trigger (valid)
Exposure
Readout
C
Time
U
30V
high
11V
4.5V
low
0
Figure 37 ▲
Trigger signal, valid for
Baumer cameras.
◄ Figure 38
Camera in trigger
mode:
A - Trigger delay
B - Exposure time
C - Readout time
Trigger Delay:
The trigger delay is a
flexible user-defined delay
between the given trigger
impulse and the image cap-
ture. The delay time can
be set between 0.0 μsec
and 2.0 sec with a stepsize
of 1 μsec. In the case of
multiple triggers during the
delay the triggers will be
stored and delayed, too.
The buffer is able to store
up to 512 trigger
signals during the delay.
Your benefits:
No need for a perfect
alignment of an external
trigger sensor
Different objects can be
captured without hardware
changes
◄ Figure 39
Examples of possible
trigger sources.
35
t